WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller
Mga pagtutukoy
- Sinusuportahang Serye: KEYENCE KV-8000, KEYENCE KV-X310
- Website: http://www.keyence.com/
Pagtuturo sa Pag-install
Setting ng HMI:
| Mga Parameter | Inirerekomenda | Mga pagpipilian | Mga Tala |
| Uri ng PLC | KEYENCE KV-8000/KV-X (Symbolic) (Ethernet) | ||
| PLC I/F | Ethernet | ||
| Port no. | 8500 | ||
| Uri ng device | KV8000 | KV8000 / KVX | |
| Online na simulator | Oo | Multi-HMI kumonekta | Oo |
I-export Tags:
Lumilikha ang software ng KV STUDIO tag:
- Variable -> Cerected tag sa Global o Lokal na talahanayan.

- Support Sturcutre address.

- I-export tag: File -> Output CSV/TXT file -> Variable na impormasyon

Mag-import Tags:
- In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags.

- Piliin ang .txt file mag-import.

- Mag-import ng ilan o lahat ng tags

- Piliin ang tag gusto mong mag-import Tag Manager, pindutin ang OK.

- Na-import tag matagumpay na impormasyon.

Uri ng Suporta ng Device
| Uri ng data | Format ng data ng EasyBuilder | Memo |
| BOOL | bit | |
| INT | 16-bit BCD, Hex, Binary, Signed | 16-bit |
| UINT | 16-bit BCD, Hex, Binary, Unsigned | 16-bit |
| DINT | 32-bit BCD, Hex, Binary, Signed | 32-bit |
| UDINT | 32-bit BCD, Hex, Binary, Unsigned | 32-bit |
| TOTOO | 32-bit na Float | 32-bit |
| LREAL | 64-bit na Float | 64-bit *Tandaan1 |
| STRING | Word array para sa ASCII input at display | *Tandaan2 |
|
Array |
BOOL, INT, UINT, DINT, UDINT, TOTOO,
LREAL, Istraktura *Tandaan3 |
|
|
Istruktura |
BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING
Array |
- Tandaan1: Ang EBPro V6.03.02 o mas bago ay sumusuporta sa 64 bits na uri ng data (cMT Series lang), ngunit pakitandaan na ang saklaw ng limitasyon ng address ay 48 bits ang maximum.
- Tandaan 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.

- Tandaan 3: Support 1~3D array, 4D arrays and above cannot be imported.
Wiring Diagram
Ethernet cable:

Mga FAQ
How do I connect multiple HMIs?
You can connect multiple HMIs using the on-line simulator option in the HMI settings.
What is the maximum string length supported for STRING data type?
In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.
Mga Dokumento / Mga Mapagkukunan
![]() |
WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdf] Gabay sa Gumagamit KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller |