SoliTek SOLID Series Solar Modules Installation Guide

SoliTek SOLID Series Solar Modules Installation Guide

SoliTek-LOGO

SoliTek SOLID Series Solar Modules

SoliTek-SOLID-Series-Solar-Modules-PRODUCT

Mga Tagubilin sa Paggamit

  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • Ang pagkabigong sundin ang mga tagubilin sa gabay na ito ay maaaring makapinsala sa mga bahagi ng system, malagay sa panganib ang mga tauhan, makapinsala sa ari-arian, o mapawalang-bisa ang warranty ng panel.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

PANGKALAHATANG KINAKAILANGAN

  • Mangyaring basahin nang buo ang gabay na ito bago ang pag-install.
  • Ang layunin ng dokumentong ito ay magbigay ng mga minimum na kinakailangan at rekomendasyon para sa ligtas at matagumpay na pag-install ng mga module ng SoliTek PV.
  • Naglalaman din ang dokumentong ito ng mga kinakailangan upang mapanatili ang pagsunod sa SoliTek PV module sa mga pamantayan ng IEC 61215, IEC 61730, UL 61730.
  • Ang gabay na ito ay naglalaman ng pangunahing impormasyon tungkol sa JSC "SoliTek Cells" SOLID series photovoltaic modules, ang kanilang pag-install at ligtas na paghawak. Dapat basahin at unawain ang lahat ng mga tagubilin bago subukang i-install. Kung mayroong anumang mga katanungan, mangyaring makipag-ugnayan sa iyong dealer o JSC "SoliTek Cells" para sa karagdagang impormasyon.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • Ang paglabag o hindi tumpak na pagsunod sa anumang sugnay ng dokumentasyong ito ay nagpapawalang-bisa sa warranty.
  • Dapat na maunawaan at sundin ng installer ang lahat ng naaangkop na lokal, estado, at pederal na regulasyon at pamantayan para sa pagtatayo ng gusali, disenyong elektrikal, sunog, at kaligtasan, at dapat suriin sa mga lokal na awtoridad upang matukoy ang naaangkop na mga kinakailangan sa pagpapahintulot bago subukang mag-install o magpanatili ng mga PV module at dapat maging pamilyar sa mga mekanikal at elektrikal na kinakailangan para sa mga photovoltaic system.
  • Ang pagkabigong sundin ang mga tagubilin sa gabay na ito ay maaaring makapinsala sa mga bahagi ng system, malagay sa panganib ang mga tauhan, makapinsala sa ari-arian, o mapawalang-bisa ang warranty ng panel.
  • Ang mga Rooftop PV system ay dapat lamang i-install sa mga tirahan na pormal na nasuri para sa integridad ng istruktura at nakumpirmang may kakayahang pangasiwaan ang karagdagang timbang na load ng mga bahagi ng PV system, kabilang ang mga PV module, ng isang sertipikadong espesyalista sa gusali o engineer.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • Ang flat-plate PV module construction ay binubuo ng isang laminated assembly ng solar cells na naka-encapsulated sa loob ng insulating material sa loob ng dalawang glass sheet.
  • Panatilihin ang dokumentasyong ito sa isang ligtas na lugar para sa sanggunian sa hinaharap.
  • Huwag subukang i-disassemble ang module, at huwag tanggalin ang anumang nakakabit na nameplate o mga bahagi! Ang paggawa nito ay mawawalan ng bisa ng warranty.

Pangangasiwa at Aplikasyon

HANDLING

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • Huwag lumampas sa pinakamataas na taas ng mga papag na isalansan, gaya ng ipinahiwatig sa packaging ng papag.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

APLIKASYON

Mga paghihigpit

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • Ang artipisyal na puro ilaw ay hindi dapat nakadirekta sa mga module ng SoliTek PV.

Mga rekomendasyon

  • Inirerekomenda ng SoliTek na ang mga module ng PV ay i-mount sa isang minimum na anggulo ng pagtabingi na 10 degrees upang payagan ang wastong paglilinis sa sarili mula sa ulan.
  • Ang bahagyang o kumpletong pagtatabing ng isang PV module o mga module ay maaaring makabuluhang bawasan ang pagganap ng system.
  • Inirerekomenda ng SoliTek na bawasan ang dami ng lilim sa buong taon upang madagdagan ang dami ng enerhiya na ginawa ng mga PV module.
  • Mataas na sistema voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage lundag.
  • Ang mas mahusay na bentilasyon ng module at mas maiikling mga kable ng koneksyon ay nagpapataas ng produksyon ng elektrikal na enerhiya.

Para sa bifacial modules:

  • Inirerekomenda na taasan ang taas ng panel ng PV mula sa lupa para mas maraming liwanag ang maaaring maglakbay sa ilalim ng module at pagkatapos ay mag-reflect
  • Ang bifacial gain ay tumataas nang malaki kung ang mga module ay naka-install sa itaas ng puti (high albedo value), light-reflecting surface.

Pag-install ng elektrikal

KALIGTASAN

  • Ang mga PV module ay maaaring gumawa ng kasalukuyang at voltage kapag nalantad sa liwanag ng anumang intensity. Tumataas ang electric current na may mas mataas na intensity ng liwanag. DC voltage ng 50 Volts o mas mataas ay potensyal na nakamamatay. Ang pakikipag-ugnayan sa live circuitry ng isang PV system na tumatakbo sa ilalim ng liwanag ay maaaring magresulta sa nakamamatay na electric shock.
  • I-de-energize ang mga PV module sa pamamagitan ng ganap na pag-alis sa mga ito mula sa liwanag o sa pamamagitan ng pagtakip sa kanilang harapan na ibabaw ng isang opaque na materyal. Tungkol sa mga regulasyon sa kaligtasan para sa mga live na de-koryenteng kagamitan kapag nagtatrabaho sa mga module na nakalantad sa anumang liwanag. Gumamit ng mga insulated na tool at huwag magsuot ng metal na alahas habang nagtatrabaho sa PV modules.
  • Upang maiwasan ang arcing at electrical shock, huwag idiskonekta ang mga de-koryenteng koneksyon sa ilalim ng pagkarga. Ang mga maling koneksyon ay maaari ding magresulta sa arcing at electrical shock. Panatilihing tuyo at malinis ang mga konektor at tiyaking nasa tamang kondisyon sa pagtatrabaho ang mga ito. Huwag kailanman magpasok ng mga metal na bagay sa mga konektor o baguhin ang mga ito sa anumang paraan upang ma-secure ang isang de-koryenteng koneksyon.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • Ang pag-install ng solar photovoltaic system ay nangangailangan ng mga espesyal na kasanayan at kaalaman. Dapat itong gawin lamang ng mga kwalipikado at espesyal na itinuro na mga tauhan. Isinasaalang-alang ng installer ang lahat ng panganib ng pinsala, kabilang ang panganib ng electric shock.
  • Gumamit lamang ng kagamitan, connector, wiring at mounting hardware na partikular na idinisenyo para gamitin sa isang photovoltaic system.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • Kapag dinidiskonekta ang mga wire na nakakonekta sa isang photovoltaic module na nakalantad sa liwanag, maaaring magkaroon ng electric arc. Ang mga arko ay maaaring magdulot ng mga paso, pagsisimula ng apoy, o kung hindi man ay lumikha ng mga problema sa kaligtasan (hanggang sa nakamamatay na electric shock).
  • Suriin ang natitirang voltage before starting and observe the local safety-relevant regulations for such working conditions.
  • Sa ilalim ng normal na mga kondisyon, ang isang photovoltaic module ay maaaring makagawa ng mas kasalukuyang at/o voltage (dito: 30V DC) kaysa sa iniulat sa karaniwang kondisyon ng pagsubok.
  • Makipag-ugnayan sa isang DC voltage ng 30 V o higit pa ay potensyal na mapanganib. Mag-ingat kapag nagbi-wire o humahawak ng mga module na nakalantad sa sikat ng araw.
  • Ikonekta lamang ang mga module na may parehong rate ng output na kasalukuyang sa serye. Kung ang mga module ay konektado sa serye, ang kabuuang voltage ay katumbas ng kabuuan ng indibidwal na module voltages.
  • Ikonekta lamang ang mga module o serye na kumbinasyon ng mga module na may parehong voltage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • Palaging gumamit ng parehong uri ng module sa loob ng isang partikular na sistemang photovoltaic.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • Gumamit ng naaangkop na kagamitang pangkaligtasan (mga insulated na kasangkapan, dielectric na guwantes, sapatos at iba pa) na inaprubahan para gamitin sa mga electrical installation.

CONFIGURATION

  • Sa ilalim ng normal na mga kondisyon, ang isang photovoltaic module ay malamang na makaranas ng mga kondisyon na gumagawa ng mas kasalukuyang at/o voltage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) ay dapat na i-multiply sa isang factor na hanggang 1.25 batay sa pinakamababa at pinakamataas na temperatura ng kapaligiran na naitala para sa lokasyon ng pag-install kapag tinutukoy ang component voltage rating, kasalukuyang rating ng conductor, laki ng fuse, at laki ng mga kontrol na konektado sa output ng PV.
  • VoltagAng mga ito ay additive kapag ang PV modules ay direktang konektado sa serye, at ang module currents ay additive kapag ang PV modules ay direktang konektado sa parallel. Ang mga PV module na may iba't ibang katangian ng kuryente ay hindi dapat direktang konektado sa serye. Ang paggamit ng angkop na mga third-party na electronic device na konektado sa PV modules ay maaaring magpagana ng iba't ibang mga de-koryenteng koneksyon at dapat na mai-install ayon sa tinukoy na mga tagubilin ng gumawa.
  • Ang maximum na voltage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Gayundin, ang maximum na input voltage ng inverter at ng iba pang mga de-koryenteng aparato sa system ay dapat isaalang-alang. Ang bukas na circuit voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

OVERCURRENT PROTECTION DEVICE (OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • piyus amp rating ≥ 1.25 x Isc
  • Piliin ang susunod na mas mataas na karaniwang rating sa catalog ng mga available na PV Fuse.
  • Isc = Short-circuit current ng isang module sa Standard Test Conditions (STC).
  • Isinasaalang-alang ang mga halaga ng Isc ng SoliTek modules, ang tamang halaga ng PV Fuse na gagamitin sa pag-install ay 30 A. Inirerekomenda ng SoliTek ang paggamit ng PV fuse sa parehong positibo at negatibong conductor.

KABLE at KAWALAN

Ang mga SoliTek PV modules ay binibigyan ng dalawang standard, sinag ng araw-resistant na mga kable na output na tinatapos na may mga PV connector na handa para sa karamihan ng mga pag-install. Ang positive (+) terminal ay may male connector habang ang negative (-) terminal ay may female connector. Ang module wiring ay inilaan para sa mga serye na koneksyon (ibig sabihin, lalaki (+) sa babae (-) na mga interconnection) ngunit maaari ding gamitin para ikonekta ang mga angkop na third-party na mga de-koryenteng device na maaaring may alternatibong mga wiring configuration hangga't sinusunod ang mga tagubilin ng manufacturer.
Gumamit ng mga field wiring na may angkop na cross-sectional na mga lugar na naaprubahan para sa paggamit sa maximum na short-circuit current ng PV module. Ang lahat ng mga kable ay dapat na double insulated, cross-linked cable na may minimum na rating na 1,8 kV (higit sa 1500 V voltage) at isang minimum na na-rate na temperatura na 90 ˚C (190 °F). Laki ng wire na hindi bababa sa 4 mm² (12 AWG). Ang uri ng pagkakabukod ay dapat na angkop para sa uri ng paraan ng pag-install na ginamit at dapat matugunan ang mga kinakailangan ng IEC 61730 at Safety Class II.

  • Antas ng pagkakabukod: 1,8 kV (conductor-conductor).
  • Temperatura: -40°C hanggang +90°C (-40 °F hanggang 190 °F) nang hindi bababa sa.
  • Konstruksyon ng konduktor: tinned stranded copper wire na may tansong kadalisayan na higit sa 99,9%.
  • Pangunahing pagkakabukod: cross-linked polyethylene (XLPE), lumalaban sa sikat ng araw at moisture, flame retardant. Angkop para sa conduit at mga raceway na naka-install sa ilalim ng lupa.
  • Insulation (jacket): thermoplastic, lumalaban sa sikat ng araw, lumalaban sa apoy, lumalaban sa tubig.
  • Minimum na panlabas na diameter ng cable na may pagkakabukod - 5,2 mm (2,05 pulgada).
  • Minimum na conductor cross-section – 4 mm² (12 AWG).

Inirerekomenda ng SoliTek ang mga installer na gumamit lamang ng mga kable na lumalaban sa sikat ng araw na kwalipikado para sa direktang kasalukuyang (DC) na mga kable sa mga PV system. Ang mga cable ay dapat na maayos sa mounting structure sa paraan na ang mekanikal na pinsala ng cable at/o ang module ay maiiwasan. Huwag lagyan ng stress ang mga cable. Para sa pag-aayos, gumamit ng naaangkop na paraan, tulad ng mga cable ties na lumalaban sa sikat ng araw at/o mga wire management clip. Habang ang mga kable ay lumalaban sa sikat ng araw at hindi tinatablan ng tubig, kung posible, iwasan ang direktang liwanag ng araw at paglubog ng tubig ng mga kable.
Ang karaniwang haba ng mga cable mula sa mga junction box ay 1,2 m (47,24 pulgada). Ito ay nilayon na ang dalawang panel ay magkakabit sa system.

GROUNDING

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
Ang mga butas na may marka ng saligan sa frame ay maaari lamang gamitin para sa saligan. Huwag mag-drill ng karagdagang mga butas sa saligan sa frame ng module.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Ang grounding conductor ay dapat na gumawa ng koneksyon sa earth gamit ang isang angkop na earth ground electrode.
A bolted connection is required; it incorporates:

  • Isang bolt na laki ng M4.
  • Ang isang tooth washer sa ilalim ng bolt head o isang serrated bolt ay dapat tumagos sa nonconductive coatings tulad ng anodized frame.
  • Isang fasten nut na angkop para sa M4 bolt.
  • Ang lahat ng hardware ay dapat na nonferrous na metal, 300-series na hindi kinakalawang na asero, o angkop na protektado ng kaagnasan.
  • Ang inirerekomendang torque ng pag-lock ng nut ay 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
  • Ang grounding bolt ay kailangang dumaan sa lahat ng mga elemento ng pagkonekta.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • Ang mga device na nakalista at natukoy para sa grounding metallic frames ng PV modules ay pinahihintulutan na i-ground ang exposed metallic frames ng module sa grounded mounting structures.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

Mga KONNEKTO

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • Huwag subukang gumawa ng de-koryenteng koneksyon gamit ang basa, marumi, o kung hindi man ay may sira na mga konektor.
  • Iwasan ang pagkakalantad sa sikat ng araw at paglubog ng tubig ng mga konektor. Iwasan ang mga konektor na nakapatong sa lupa o ibabaw ng bubong.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • Suriin na ang lahat ng mga de-koryenteng koneksyon ay ligtas na nakakabit. Siguraduhin na ang lahat ng locking connector ay ganap na nakadikit at naka-lock.

BYPASS DIODES

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Ang mga bypass diode ay hindi mga overcurrent na proteksyon na aparato. Ang mga bypass diode ay naglilihis ng kasalukuyang mula sa mga string ng cell kung sakaling may bahagyang pagtatabing. Ang mga katangian ng mga diode na ito:

  • Voltage rating – 50 V.
  • Kasalukuyang rating – 25 A.

RATING NG FIRE CLASS

  • Ang mga SoliTek SOLID Bifacial at Blackstar modules ay naaprubahan ng IEC fire test at nakamit ang Flammability Class A. Ang pagsubok sa sunog ay isinagawa sa inklinasyon na 127 mm (5 pulgada) bawat 300 mm (11,81 pulgada), gaya ng inireseta sa punto A.2.5 ng IEC 61730-2.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

Pag-mount ng mekanikal

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

PANGKALAHATANG KINAKAILANGAN

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • Mangyaring sundin ang mga regulasyon sa kaligtasan at mga tagubilin sa pag-install na kasama ng mounting system. Kung kinakailangan, mangyaring makipag-ugnayan nang direkta sa supplier para sa karagdagang impormasyon.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • Siguraduhin na ang mounting rail ay hindi magde-deform o makakaapekto sa mga module kapag lumawak ito bilang resulta ng thermal expansion.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • Huwag subukang mag-drill ng mga butas sa ibabaw ng salamin at ang mga frame ng mga module dahil mawawalan ito ng garantiya.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

Ang mga mounting component ay dapat na gawa sa matibay, anti-corrosive at UV-resistant na materyales (inirerekumenda ang stainless steel at anodized aluminum component).

MOUNTING WITH CLAMPS

  • Gumamit ng hindi bababa sa 4 laminate clamps upang ayusin ang mga module sa mounting rails. Mga module clampAng mga bahaging metal ay hindi dapat madikit sa harap o likod na salamin. Kapag pumipili ng ganitong uri ng clamp-mounting method, gumamit ng hindi bababa sa apat na clamps sa bawat modyul; dalawang clamps ay dapat na naka-attach sa bawat mahabang gilid. Depende sa lokal na hangin at snow load, karagdagang clamps ay maaaring kailanganin upang matiyak na ang mga module ay maaaring dalhin ang pagkarga.
  • Clamps tightening torque ay dapat na hindi bababa sa 15 Nm (11,06 ft-lb), ngunit hindi hihigit sa 20 Nm (14,75 ft-lb). Karaniwan, ang 15 Nm (11,06 ft-lb), ay naaabot kapag ang dalawang aluminum profiles magkadikit. Kapag naka-install ang isang module sa portrait na oryentasyon sa naka-pitch na bubong na may >45° slope, kinakailangan ang karagdagang hook sa ibaba ng module.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

Na may transversal rails

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • Kapag pumipili ng ganitong uri ng clamp-mounting method, gumamit ng hindi bababa sa apat na clamps sa bawat modyul; dalawang clamps ay dapat na nakalakip sa bawat panig ng module. Mga module clamps ay hindi dapat makipag-ugnayan sa harap na salamin at hindi dapat ma-deform ang frame.
  • Siguraduhing iwasan ang mga epekto ng anino sa mga solar cell mula sa module clamps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • Ang haba ng clamp should be at least 30 mm (1,18 inch).
  • Ang clamp dapat mag-overlap ang module frame ng hindi bababa sa 5 mm (0,2 pulgada), ngunit hindi hihigit sa 10mm (0,4 pulgada).

Na may transversal rails

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

Kung walang transversal rails o riles ay patayo sa mahabang side frame

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

Gamit ang insertion system

SoliTek-SOLID-Series-Solar-Modules-FIG-12

Pag-mount na may bolts

  • Ang module ay dapat na ikabit at sinusuportahan ng apat na M8 stainless steel bolts sa pamamagitan ng ipinahiwatig na mga mounting hole sa mga transversal bar. Torque sa clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampang hardware ay kailangang piliin.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • Ang pagbabarena ng mga bagong butas ay ipinagbabawal at mawawalan ng bisa ang warranty.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

POSISYON NG JUNCTION BOX

  • Para sa distansya sa pagitan ng junction box at gilid ng module o iba pang dimensyon ng junction box na posisyon at mga lugar mangyaring sumangguni sa mga figure na ipinapakita sa ibaba.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

MAINTENANCE

  • Upang matiyak ang pinakamabuting pagganap ng module, inirerekomenda ng SoliTek ang mga sumusunod:
  • Kung kinakailangan, ang salamin sa harap ng module ay maaaring linisin ng tubig at isang malambot na espongha o tela.
  • Maaaring gumamit ng banayad at hindi nakasasakit na sabong panlaba upang alisin ang mas matigas na mantsa.
  • Pana-panahong suriin ang mga de-koryente at mekanikal na koneksyon at tiyaking malinis, ligtas, kumpleto at ligtas ang mga ito.
  • Kung sakaling magkaroon ng problema, kumunsulta sa isang lisensyado/kwalipikadong tao.

MGA ESPISIPIKASYON

Parameter \ Modelo BLACKSTAR B.96 SOLID Black (Semi-Clear) B.96 35(40) mm BLACKSTAR Satin B.96 MAGNUS B.108
Mga kondisyon ng pagsubok STC STC STC STC
Nominal na kapangyarihan 455 W 455 W 445 W 510 W
Data ng Elektrisidad @STC
Pinakamataas na Power (Pmax), W 455 455 445 510
Voltage sa Maximum Power (Vmpp), V 29,71 29,71 29,40 33,34
Kasalukuyan sa Maximum Power (Impp), A 15,31 15,31 15,14 15,30
Buksan ang Circuit Voltage (Voc), V 34,82 34,82 34,40 39,06
Short Circuit Current (Isc), A 15,97 15,97 15,79 15,95
Thermal Data
Saklaw ng Operating Temperatura -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Temperature Coefficient ng Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F) -0,362%/°C (°F)
Temperature Coefficient ng Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F) -0,265%/°C (°F)
Temperature Coefficient ng Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F)
Data ng laki at timbang
Ang haba 1762 mm 1762 mm 1762 mm 1961 mm
Lapad 1134 mm 1134 mm 1134 mm 1134 mm
kapal 30 mm 35(40) mm 30mm 30 mm
Timbang 25,5 kg 35(36) kg 25,5 kg 28,5 kg
Paraan ng pag-mount
Reference to the chapter 3.3 3.3 3.3 3.3
Iba pa
Pinakamataas na reverse current, A 30
Fire    class, IEC 61730/UL 61730 A/Uri II
Maximum system voltage, V 1500

Table 9. Electrical and mechanical parameters table.

Parameter \ Modelo SOLID Semi- clear B.96 SOLID Black B.96 SOLID Satin B.96 SOLID Agro B.64
Mga kondisyon ng pagsubok STC STC STC STC
Nominal na kapangyarihan 455 W 455 W 445 W 300 W
Data ng Elektrisidad @STC
Pinakamataas na Power (Pmax), W 455 455 445 300
Voltage sa Maximum Power (Vmpp), V 29,71 29,71 29,40 19,60
Kasalukuyan sa Maximum Power (Impp), A 15,31 15,31 15,14 15,31
Buksan ang Circuit Voltage (Voc), V 34,82 34,82 34,40 22,76
Short Circuit Current (Isc), A 15,97 15,97 15,79 15,97
Thermal Data
Saklaw ng Operating Temperatura -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Temperature Coefficient ng Pmax -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Temperature Coefficient ng Voc -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Temperature Coefficient ng Isc +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Data ng laki at timbang
Ang haba 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
Lapad 1144±2 1144±2 1144 ± 2 mm 1144 ± 2 mm
kapal 7,2 mm 7,2 mm 7,2 mm 7,2 mm
Timbang 33kg 33 kg 33 kg 33 kg
Paraan ng pag-mount
Reference to the chapter 3.2 3.2 3.2 3.2
Iba pa
Pinakamataas na reverse current, A 30
Fire    class, IEC 61730/UL 61730 A/Uri II
Maximum system voltage, V 1500

Table 10. Electrical and mechanical parameters table.

Parameter \ Modelo SOLID Satin B.96 35 mm SOLID Satin B. 96 40 mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
Mga kondisyon ng pagsubok STC STC STC STC
Nominal na kapangyarihan 445 W 445 W 300 W 300 W
Data ng Elektrisidad @STC
Pinakamataas na Power (Pmax), W 445 445 300 300
Voltage sa Maximum Power (Vmpp), V 29,40 29,40 19,60 19,60
Kasalukuyan sa Maximum Power (Impp), A 15,14 15,14 15,31 15,31
Buksan ang Circuit Voltage (Voc), V 34,40 34,40 22,78 22,78
Short Circuit Current (Isc), A 15,79 15,79 15,97 15,97
Thermal Data
Saklaw ng Operating Temperatura -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F) -40oC ÷ 85oC (-40°F ÷ 185°F)
Temperature Coefficient ng Pmax -0,362%/°C (°F) -0,362%/°C (°F) -0,30%/°C (°F) -0,30%/°C (°F)
Temperature Coefficient ng Voc -0,265%/°C (°F) -0,265%/°C (°F) -0,25%/°C (°F) -0,25%/°C (°F)
Temperature Coefficient ng Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Data ng laki at timbang
Ang haba 1762mm 1762mm 1762 mm 1762 mm
Lapad 1134 mm 1134 mm 1134 mm 1134 mm
kapal 35 mm 40 mm 35 mm 40 mm
Timbang 35 kg 36kg 35 kg 36 kg
Paraan ng pag-mount
Reference to the chapter 3.3
Iba pa
Pinakamataas na reverse current, A 30
Fire    class, IEC 61730/UL 61730 A/Uri II
Maximum system voltage, V 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • Ang lahat ng mga panel ng SoliTek SOLID PV ay tumutugma sa electrical safety class II.

Disclaimer ng pananagutan

  • Dahil imposible para sa SoliTek na kontrolin ang pag-install, operasyon, aplikasyon at pagpapanatili ng photovoltaic system ayon sa tagubiling ito. Ang SoliTek ay hindi tumatanggap ng responsibilidad at hayagang itinatanggi ang pananagutan para sa anumang pagkawala, pinsala o gastos na nagmumula sa o sa anumang paraan na konektado sa naturang pag-install, pagpapatakbo, paggamit o pagpapanatili.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

FAQ

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

Mga Dokumento / Mga Mapagkukunan

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

Mga sanggunian

Magtanong

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Magtanong

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.