nvent--LOGO

kaganapan HOFFMAN LC02 Floor Standing Enclosures Combinable Compact Version

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-PRODUCT

Impormasyon ng Produkto

Mga pagtutukoy:

  • Pangalan ng Produkto: Floor Standing Enclosures
  • Mga Bersyon: Combinable at compact

Mga Tagubilin sa Paggamit ng Produkto

Mga Tagubilin sa Pag-mount:

Upang i-mount ang floor-standing enclosure, sundin ang mga hakbang sa ibaba:

  1. Tukuyin ang iba't ibang bahagi ng enclosure, kabilang ang rear panel, side panel, roof plate, mounting plate, pinto, at bottom plate.
  2. Piliin ang naaangkop na bersyon ng enclosure batay sa iyong mga kinakailangan: MCS, MCD, MKS, o MKD.
  3. Tiyaking mayroon kang mga kinakailangang kagamitan at tool para sa pag-mount, kabilang ang mga turnilyo at isang torque wrench.
  4. Kung naka-mount sa o sa ibabaw ng nasusunog na ibabaw, mag-install ng floor plate na hindi bababa sa 1.43 mm galvanized o 1.6 mm na uncoated na bakal na pinahaba ng hindi bababa sa 150 mm na lampas sa kagamitan sa lahat ng panig.
  5. Para sa mga naka-customize na enclosure, gumamit ng mga device na may parehong environmental rating para isara ang mga opening at mapanatili ang integridad ng kapaligiran.

Bersyon ng MCS:

Upang i-mount ang bersyon ng MCS ng floor standing enclosure, sundin ang mga hakbang sa ibaba:

  1. Ikabit ang rear panel sa side panel gamit ang mga ibinigay na turnilyo.
  2. I-mount ang roof plate sa naka-assemble na mga panel sa likuran at gilid.
  3. Ikabit ang mounting plate sa ilalim ng enclosure.
  4. I-install ang pinto sa harap ng enclosure.

Bersyon ng MCD:

Upang i-mount ang bersyon ng MCD ng floor standing enclosure, sundin ang mga hakbang sa ibaba:

  1. Ikabit ang rear panel sa side panel gamit ang mga ibinigay na turnilyo.
  2. I-mount ang roof plate sa naka-assemble na mga panel sa likuran at gilid.
  3. Ikabit ang mounting plate sa ilalim ng enclosure.
  4. I-install ang mga pinto sa harap at likod ng enclosure.

Bersyon ng MKS:

Upang i-mount ang MKS na bersyon ng floor standing enclosure, sundin ang mga hakbang sa ibaba:

  1. Ikabit ang rear panel sa side panel gamit ang mga ibinigay na turnilyo.
  2. I-mount ang roof plate sa naka-assemble na mga panel sa likuran at gilid.
  3. Ikabit ang mounting plate sa ilalim ng enclosure.
  4. I-install ang pinto sa harap ng enclosure.

Bersyon ng MKD:

Upang i-mount ang MKD na bersyon ng floor standing enclosure, sundin ang mga hakbang sa ibaba:

  1. Ikabit ang rear panel sa side panel gamit ang mga ibinigay na turnilyo.
  2. I-mount ang roof plate sa naka-assemble na mga panel sa likuran at gilid.
  3. Ikabit ang mounting plate sa ilalim ng enclosure.
  4. I-install ang mga pinto sa harap at likod ng enclosure.

 FAQ

T: Kailangan ko bang mag-install ng floor plate kapag naka-mount sa nasusunog na ibabaw?

A: Oo, kapag naka-mount sa ibabaw o sa ibabaw ng nasusunog na ibabaw, dapat na naka-install ang floor plate na hindi bababa sa 1.43 mm galvanized o 1.6 mm uncoated steel na hindi bababa sa 150 mm na lampas sa kagamitan sa lahat ng panig.

T: Paano ko mapapanatili ang integridad ng kapaligiran ng isang naka-customize na enclosure?

A: Upang mapanatili ang integridad ng kapaligiran ng enclosure, ang mga device na may parehong mga environmental rating ay dapat gamitin upang isara ang mga opening sa customized na enclosure.

MGA BAHAGI

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG1 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG2

BABALA: Kapag naka-mount sa o sa ibabaw ng nasusunog na ibabaw, dapat na naka-install ang floor plate na hindi bababa sa 1.43 mm galvanized o 1.6 mm uncoated steel na hindi bababa sa 150 mm na lampas sa kagamitan sa lahat ng panig.

BABALA: Upang mapanatili ang integridad ng kapaligiran ng enclosure, ang mga device na may parehong mga environmental rating ay dapat gamitin upang isara ang mga opening sa customized na enclosure

MGA INSTRUKSYON SA PAG-INSTALL

MCS

 

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG3.

MCD

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG4

MKS

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG5

MKD

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG6

COMBINABLE ENLOSURE

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG7

COMBINABLE ENLOSURE

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG8

PAGSASAMA NG LIFT HANDLE

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG9 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG10 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG11 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG12

TANDAAN: Ang mga transparent na takip ay iniutos nang hiwalay

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG13

MOUNTING LSEL

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG14

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG15

  1. Ginagamit sa mga enclosure na 800mm ang lalim at mas mataas.
  2. Halaga ng torque para sa unang paghihigpit. Para sa mga sumusunod na tightening, torque value na inirerekomenda ay 4-5 Nm

MCS BACK PANEL

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG16

MKS BACK PANEL

 

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG17

MKD BACK PANELS

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG18

BOTTOM PLATE

 

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG19

  • Ginagamit lamang sa 1200mm na lapad na mga enclosure.

MOUNTING PLATE

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG20

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG35

MOUNTING PLATE 1600 WIDE

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG21

MPD02

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG22

SPM

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG23 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG24 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG25 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG26

CCM 04

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG27

  • Tandaan: Lahat ng apat na bracket ay dapat na naka-install sa lahat ng apat na sulok!
  • Ang mga butas sa pag-aayos ay maaaring gamitin upang mas mahusay na ayusin ang bracket sa frame, gamit ang cage * nuts at turnilyo!

MPF

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG28

DHN 180

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG29

DHN 180 DOOR ADJUSTMENT

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG30 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG31

CNM

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG32 nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG33

MCM Mousepad RH papunta sa LH

nvent-HOFFMAN-LC02-Floor-Standing-Enclosures-Combinable-Compact-Version-FIG34

Mga Dokumento / Mga Mapagkukunan

nvent HOFFMAN LC02 Floor Standing Enclosures Combinable Compact Version [pdf] Manwal ng Pagtuturo
LC02 Floor Standing Enclosures Combinable Compact Version, LC02, Floor Standing Enclosures Combinable Compact Version, Standing Enclosures Combinable Compact Version, Combinable Compact Version, Compact Version

Mga sanggunian

Mag-iwan ng komento

Ang iyong email address ay hindi maipa-publish. Ang mga kinakailangang field ay minarkahan *