- LCU1S is the new smaller, lighter and faster AiM Lambda Controller expansion supported by all the last car-bike AiM devices.
Mangyaring tandaan: the only systems that does not support LCU1S are MXL, MXL2 and MyChron. - Nagbibigay-daan sa iyo ang LCU1S na perpektong ibagay ang carburation ng makina pati na rin ang pagpapabuti ng performance ng makina.
- Gumagamit ang LCU1S ng Bosch LSU4.9 probe na nagse-save sa orihinal na pagkakalibrate para sa tagal ng buhay ng sensor at tumatagal ng higit sa 100.000 km sa isang stock car.
Magagamit na mga kit, opsyonal at ekstrang bahagi
Ang mga available na LCU1S kit ay:
- LCU1S complete kit; part number: X08LCU1SAC090
- LCU1S
- Bosch LSU 4.9 Lambda probe
- Thread iron ring para sa pag-install
LCU1S kit without Lambda probe; part number: X08LCU1SAC0
- LCU1S
Optionals7 and spare parts:
- Bosch LSU 4.9 Lambda probe X05LSU490
- Thread iron ring for installation LBS552680
- 50cm AiM CAN cable V02552690
- 100cm AiM CAN cable V02552700
- 200cm AiM CAN cable V02552720
- 400cm AiM CAN cable V02551070
Configuring LCU1S
Ang LCU1S ay maaari lamang i-configure gamit ang AiM RaceStudio 3 software na malaya mong mada-download mula sa AiM website sa www.aim-sportline.com mag-download ng software/firmware area.
LCU1S is an expansion that is to be loaded on AiM device configuration so first of all run the software and select the configuration where to load LCUS1S on or create a new one as shown here below. To create a new configuration:
- Press “New Configuration” (1)
- Select the device you are configuring (Solo 2 DL v2 in the example below 2)
- Pindutin ang "OK" (3)

Ang software ay pumapasok sa tab na "Mga Channel".

To load LCU1S activate “CAN Expansions” (1) tab as shown here below and follow these steps:
- Press “New Expansion” (2)
- Select LCU1S (3)
- Pindutin ang "OK" (4)

Once the expansion added, the software enters the related tab (0LC1S). Here it is possible to:
- Get the serial number of LCU1S or fill it in manually (1); please note: to get the serial number from the connected LCU1S it is necessary to power it and connect the master device LCU1S is connected to your PC via Wi-Fi (or via USB). Please refer to the user manual of each logger to know how to manage Wi-Fi connection;
- select the multiplier to calculate AFR from Lambda value
- manage custom values through the dedicated panel that is prompted clicking the proper button
- As far as the channel table (2) is concerned, clicking on each channel it is possible to set sampling frequency, Yunit ng sukat at katumpakan ng pagpapakita.

How to get the serial number of a connected LCU1S
To get the serial number of the connected LCU1S ensure that LCU1S is powered and connect the master logger to the PC. To do so:
- click the Wi-Fi icon top right of the software view (or plug the USB cable of the logger in the PC USB port)
- Select the logger to connect via Wi-Fi and press “Connect”.
Once the logger connected press “Get Expansion Serial Number” as shown here below- A panel is prompted: select the connected expansion to configure and press “OK”

- the software comes back to “CAN Expansions” tab and shows LCU1S Serial number.

Online view at pag-update ng firmware
Once LCU1S connected and identified it is suggested to complete, save and transmit the configuration to the logger. This procedure changes according to the logger that is being configured.
Ngayon ay posible nang pumasok online view and check LCU1S values. To do so:
- ipasok ang "Configurations" view
- Press the logger you are configuring as shown here below.

Ang software ay pumasok sa Online view:
- Activate “Firmware” tab
- Ang view ipinapakita ang logger at ang mga pagpapalawak nito sa kanang bahagi ng view tulad ng ipinapakita sa ibaba.

To update both logger and expansions firmware:
- click the related button top right of the view
the software enters firmware update view where it is possible to download and install the firmware as for any AiM device.

Mga teknikal na pagtutukoy at mga guhit
LCU1S technical specifications are
- Sensor compatibility Bosch LSU4.
- Power supply voltage 9-15V
- Power supply current 50mA ÷ sensor heater typical current 750 mA up to 2A on cold sensor
- Reaction time Less than 10msec
- Material Latigloss 57
- Mga sukat 43.4x30x18.4 mm
- Timbang 70g
- Hindi tinatagusan ng tubig IP67
LCU1S Dimensions in mm [inches]

LCU1S Pinout

Mga Madalas Itanong
Which AiM devices are not compatible with LCU1S?
MXL, MXL2, and MyChron are the systems that do not support LCU1S.
What is the lifespan of the Bosch LSU4.9 probe?
The probe lasts for more than 100,000 km on a stock car.