1. Panimula

The Haozee Smart Gas Leakage Alarm Detector is a crucial safety device designed to monitor and detect the presence of various combustible gases in your home or office. It provides early warning of potential gas leaks, helping to prevent hazards such as fires and explosions. This device is available in two versions: a Wi-Fi version that operates independently and a Zigbee version that requires a Tuya Zigbee hub for functionality. Both versions integrate with smart home platforms for enhanced control and monitoring.

Haozee Smart Gas Leakage Alarm Detector, showing two units with EU plugs and an alarm indicator.
Figure 1: Haozee Smart Gas Leakage Alarm Detector (EU Plug Version)

2. Impormasyong Pangkaligtasan

This device is intended to detect combustible gases. It is not a substitute for proper ventilation, maintenance of gas appliances, or a carbon monoxide detector. Always prioritize safety and follow these guidelines:

  • Do not block the detector's ventilation holes.
  • Huwag pintura ang detector.
  • Regularly test the detector as described in this manual.
  • In case of an alarm, follow the "Alert Handling" procedures immediately.
  • Ensure the device is installed in an appropriate location based on the type of gas being detected.

3. Over Productview

The Haozee Smart Gas Leakage Alarm Detector features a high-stability semiconductor gas sensor designed for sensitive and responsive detection of various combustible gases. It provides a loud alarm (70dB/m) and can be integrated into smart home systems for remote monitoring and control.

3.1. Mga Pangunahing Tampok

  • Combustible Gas Detection: Detects natural gas, liquefied gas (LPG), bio-gas, and methane (CH4).
  • Two Versions: Available in Wi-Fi (no hub required) and Zigbee (requires Tuya Zigbee hub) variants.
  • Pagsasama ng Smart Home: Mobile APP control for monitoring and alerts.
  • High Decibel Alarm: Audible alert at 70dB/m.
  • Fault Self-Check: Energy-saving and low-consuming self-test function.
  • Plug and Play: Easy installation with replaceable plugs for different regional standards (US, UK, EU).
  • Intelligent Linkage (Zigbee version): Can be linked with a Wi-Fi valve manipulator to automatically shut off gas in case of a leak.
Diagram showing the gas detector and icons for Liquefied gas, natural gas, Bio-gas, and CH4, indicating the types of combustible gases it can detect.
Figure 2: Types of Combustible Gases Detected
Infographic detailing features of the Zigbee combustible gas detector: Mobile APP Control, Intelligent linkage, High Decibel Alarm, Remote Valve Shut-Off, Fault self check, Plug and Play.
Figure 3: Zigbee Version Key Features

4. Mga pagtutukoy

ParameterHalaga
Nagtatrabaho VoltageAC 85V-250V
Average na Pagkonsumo≤1.5W
Tunog ng Alarm70dB/m (or 70dB at 1M for Zigbee)
Alarm Density (CH4)6%LEL ± 3%LEL (for Wi-Fi) / 7% LEL ± 3% LEL (for Zigbee)
Pamantayan sa Wi-Fi802.11b/g/n (for Wi-Fi version)
Zigbee StandardZigbee 3.0 (for Zigbee version)
Working Frequency (Zigbee)2.405~2.480GHz (for Zigbee version)
Temperatura sa Paggawa-10 ℃ ~ 50 ℃
Humidity sa Paggawa≤95%RH
Pangalan ng ProduktoDetektor ng gas
PinagmulanMainland China
Diagram showing product dimensions (48mm height, 55mm width, 30mm depth) and a table of specifications including Working Voltage, Average Consumption, Alarm Sound, Alarm Density, WIFI Standard, Working Temperature, and Working Humidity.
Figure 4: Mga Dimensyon at Detalye ng Produkto

5. Pag-setup

5.1. Lokasyon ng Pag-install

Correct installation is critical for effective gas detection. The placement depends on whether the gas to be detected is heavier or lighter than air.

  • For gases heavier than air (e.g., LPG, Propane): Install the detector at 0.3-1 meter height from the floor. The semi-diameter to the gas source should be less than 1.5 meters.
  • For gases lighter than air (e.g., Natural Gas, Methane, Manufactured Gas, Marsh Gas): Install the detector at 0.3-1 meter height from the ceiling. The semi-diameter to the gas source should be less than 1.5 meters.

Avoid installing the detector in areas with strong air currents, near ventilation openings, or in places where it might be obstructed.

Installation diagram showing placement of the gas sensor relative to the ceiling, floor, and a gas stove. It indicates a 0.3-1m distance from the ceiling/floor and a maximum diameter of 3m from the gas source.
Larawan 5: Diagram ng Pag-install
Image showing the gas detector with interchangeable US, UK, and EU plug types, highlighting its plug-and-play design.
Figure 6: Plug and Play with various plug standards (US, UK, EU)

5.2. Pag-on

Plug the detector into a standard AC 85V-250V power outlet. The device will initiate a self-test sequence upon power-up.

5.3. Connecting to Smart Home System

For Wi-Fi Version:

  • Download the Tuya Smart or Smart Life app from your mobile app store.
  • Magrehistro o mag-log in sa iyong account.
  • Follow the in-app instructions to add a new device. The Wi-Fi version does not require a separate hub.

For Zigbee Version:

  • Ensure you have a Tuya Zigbee hub (gateway) already set up and connected to your smart home app.
  • Download the Tuya Smart or Smart Life app from your mobile app store.
  • Magrehistro o mag-log in sa iyong account.
  • Follow the in-app instructions to add a new sub-device under your Zigbee hub.

6. Mga Tagubilin sa Pagpapatakbo

6.1. Self-Test Function

The device features a self-test button on the unit itself and also within the mobile application. Pressing this button will test the alarm and buzzer functionality. The red LED will flash, and the buzzer will beep, indicating normal operation.

Image showing the gas detector with a battery icon and red sound waves, indicating a 'Failure self-test' feature for energy saving and low consumption.
Figure 7: Failure Self-Test Feature

6.2. Alarm Behavior

When the concentration of detected gas reaches or exceeds the preset alarm threshold (e.g., 6%LEL for CH4), the detector will automatically enter a continuous alarm state. This includes a loud audible alarm and, if connected to the app, notifications to your smartphone.

Image of the gas detector alarming in a kitchen setting with gas/smoke emanating from a stove, illustrating its sensitive and loud alarming capability.
Figure 8: Sensitive and Loud Alarming

6.3. Alert Handling Procedures

In the event of a gas alarm, immediately take the following actions:

  1. Close the main gas pipeline valve immediately.
  2. Extinguish all sources of ignition (e.g., open flames, cigarettes) and avoid using anything that generates sparks.
  3. Do not switch any electrical appliances ON or OFF (lights, fans, etc.) as this can create sparks.
  4. Immediately open windows and doors to ventilate the indoor air.
  5. If the alarm persists or you suspect a significant leak, evacuate the premises and contact your gas provider or emergency services.

7. Pagpapanatili

  • Regular na Pagsusuri: Perform a self-test using the button on the device or through the app at least once a month to ensure proper functionality.
  • Paglilinis: Gently wipe the exterior of the detector with a soft, dry cloth. Do not use cleaning agents, solvents, or abrasive materials, as these can damage the sensor. Ensure the ventilation holes are free from dust and debris.
  • Iwasan ang Sagabal: Periodically check that nothing is blocking the detector's sensor or alarm output.

8. Pag-aayos ng solusyon

ProblemaPosibleng DahilanSolusyon
Detector not powering onNo power to outlet; faulty unit.Check power outlet with another device. Ensure plug is fully inserted. If still no power, contact support.
Alarm not sounding during self-testBuzzer malfunction; internal fault.Ensure the self-test button is pressed firmly. If no sound, the unit may be faulty; contact support.
Maling mga alarmaInterference from cooking fumes, aerosols, or improper placement.Relocate the detector away from cooking areas, strong fumes, or high humidity. Ensure proper ventilation in the area.
Wi-Fi/Zigbee connection issuesWeak signal; incorrect setup; Zigbee hub not connected (for Zigbee version).Ensure the detector is within range of your Wi-Fi router or Zigbee hub. Check your network connection. For Zigbee, verify the hub is online and the device is correctly paired. Reset the device and try pairing again.
Alarm sounds but no gas detectedSensor sensitivity; residual gas; environmental factors.Ventilate the area thoroughly. Perform a self-test. If false alarms persist, consider environmental factors or contact support.

9. Mga Tip sa Gumagamit

  • Know Your Gas Type: Confirm whether your household gas is heavier (LPG, propane) or lighter (natural gas, methane) than air to ensure correct installation height.
  • Mahalaga ang Zigbee Hub: If you purchased the Zigbee version, remember that a Tuya Zigbee hub is required for the device to function and connect to your smart home system. The Wi-Fi version does not need a separate hub.
  • LEL Setting: The alarm density (Lower Explosive Limit or LEL) is a pre-set value for safety and is not user-adjustable. The device is designed to trigger an alarm well before dangerous concentrations are reached.
  • Pagsasama ng App: Utilize the Tuya Smart or Smart Life app for remote monitoring, receiving alerts, and performing remote self-tests, adding an extra layer of security.
  • Consider Linkage: For Zigbee users, explore linking the detector with a compatible Wi-Fi valve manipulator for automatic gas shut-off in case of a leak, providing an advanced safety measure.

10. Warranty at Suporta

Para sa impormasyon tungkol sa warranty, teknikal na suporta, o mga katanungan tungkol sa serbisyo, mangyaring sumangguni sa impormasyon sa pakikipag-ugnayan na ibinigay ng iyong retailer o ng opisyal na tanggapan ng tagagawa. website. Itago ang iyong resibo sa pagbili bilang patunay ng pagbili.