AutomationDirect CM5 Series Color Tft LCD Touch Screen

Mga pagtutukoy
- Pangalan ng Produkto: C-more CM5-RHMI Touch Panel
- Ethernet switch: 10/100 Base T PC
- Interface: Ethernet Port with Auto MDI/MDI-X
- Pagkakakonekta: Ethernet CAT5 Cable
- Manual ng Gumagamit: CM5-RHMI-USER-M Hardware User Manual, 1st Edition,Revision D
Mga Tagubilin sa Paggamit ng Produkto
Pindutin ang Panel Runtime Error
The touch panel may encounter runtime errors that could affect communication with connected PLCs. Below are the common runtime errors:
Error No. RTE-001
Mensahe ng Error: Hindi sapat ang Memory Space sa %Device%
Dahilan: The size of the destination memory is insufficient to store the data.
Error No. RTE-002
Mensahe ng Error: Nabigo ang Log. Hindi mahanap ang %Device%.
Dahilan: No device is available or the device is defective.
Error No. RTE-003
Mensahe ng Error: Nabigo ang Log. Hindi magsulat file -%file%
Dahilan: Logging the data failed due to issues like memory write protection being enabled.
Error No. RTE-004
Mensahe ng Error: Puno na ang memorya ng cache ng log
Dahilan: Puno na ang data log buffer sa SRAM memory.
Mga Error sa Pakikipagkamay
Handshake errors occur when communication timeouts or connection issues arise. Below are some common handshake errors:
Panimula
Ang mga C-more touch panel ay may mga diagnostic na built-in sa operating system na sumusubaybay sa iba't ibang runtime function na magpapakita ng mensahe ng error sa display ng panel na nagsasaad na may partikular na error na naganap at kung ano ang kinakatawan ng error. Ang (mga) Error Message ay ipinapakita sa kaliwang bahagi sa itaas ng display screen. Ang Runtime Errors ay naka-log in din sa Error log ng panel sa ilalim ng tab na Impormasyon sa System Setup Screens ng panel. Ang Error Log Code, halample RTE-004, identifies the error on the System Screen – Error tab and in the error log. See Chapter 5: System Setup Screens for additional details. The tables that follow show the possible Runtime Errors.
The user can include in their touch panel project the use of this diagnostic information by using the system tag pangalanan ang SYS ERR ERRORCODE upang kontrolin ang mga ipinapakitang screen, mga mensahe ng operator, atbp., at ipaalam din ang impormasyon ng error sa PLC o controlling device. Kung ang isang runtime error ay nangyari, ang SYS ERR ERRORCODE system tag ay maglalaman ng numerong halaga na ipinapakita sa ilalim ng Tag Code Error Value.
Para kay exampKung ang proyekto ng panel ay na-configure upang mag-log sa USB at walang USB flash drive na naka-install sa panel, ang panel ay magpapakita ng "RTE-004 Log buffer memory ay puno" at ang SYS ERR ERRORCODE system tag will contain the value 2004. The value of the last runtime error detected will remain in the SYS ERR ERRORCODE.
If you have difficulty determining the cause of the error, refer to Chapter 8: Troubleshooting for additional help or contact our technical support group at 770- 844-4200

Mga Error sa Runtime
Kasama sa sumusunod na talahanayan ang lahat ng mga error code at mga mensahe ng error na ipapakita ng panel kung ang nakalistang dahilan ay nakita. Ang lahat ng mga error na ito ay nagsasangkot ng mga problema na maaaring magresulta sa pakikipag-ugnayan ng panel sa konektadong PLC. Magkaroon ng kamalayan na hindi lahat ng mga error sa panel ay ginagamit sa bawat uri ng PLC na maaaring konektado sa panel.




Tapos na ang Seryeview
C-more CM5 Series Touch Panels
- Compatible with EA9 project versions 6.73 or newer
- Analog touch screen
- 16.7-million colors LCD for enhanced graphics
- Mga resolution ng screen hanggang 1920 X 1080 pixel
- FTP client/server
- E-mail client
- Webserver (Secure HTTPs)
- Kliyente ng MQTT
- LED na nako-configure ng user sa harap ng panel
- Project simulation
- Up to (2) Ethernet ports
- Up to 3 serial ports, RS-232C, RS422/485
- Up to (4) USB-A ports for logging, backups,and HID devices
- Programming sa pamamagitan ng USB o Ethernet
- Libu-libong mga built-in na simbolo at Windows font
- Network time server/client
- JPEG and JPG graphic object support
- Ethernet Remote Access
- Nako-customize na label sa harap ng panel
- 2-year warranty from date of purchase

C-more 7” TFT Color Touch Panel
C-more CM5 series touch screen HMI, 7.0-inch color TFT LCD, 16.7M colors, 800 x 480 pixel WVGA screen resolution, 800 MHz CPU, 12–24 VDC powered, NEMA 4/4X, IP65 (when mounted correctly; for indoor use only). Includes (1) Ethernet, (2) serial and (2) USB ports and (1) memory card slot. Compatible with CM5-PGMSW programming software v8.0 or later.


Mga tampok
- 7.0” diagonal color TFT (thin film transistor) LCD display with 16.7M colors
- 800 x 480 pixel na resolution
- 310 nits display brightness
- 50,000 hour average backlight half-life
- Analog resistive (1024 X 1024) touch screen allowing unlimited touch areas
- (1) USB port B (program/download)
- (1) USB port A (USB device options)
- Ethernet 10/100 Base-T port (program/download & PLC communication)
- Ethernet Remote Access
- Serial PLC interface (RS-232C/422/485)
- Horizontal or portrait mounting
- One built-in SD memory card slot
- 12–24 VDC powered
- 45MB project memory
- Pag-log ng data
- 0 to 50°C [32 to 122°F] operating temperature range
- NEMA 4/4X, IP65 compliant when mounted correctly, indoor use only
- Slim design saves enclosure space
- Works with Remote HMI Mobile App
Mga Port ng Komunikasyon

Mga Dimensyon ng Ginupit

C-more Selection Guide & Specifications






Mga Protokol ng Komunikasyon


Mga Kable sa Komunikasyon


Tandaan – Refer to the appropriate User Manual for specific cable pinouts, communication protocols and connection instructions.
Mga accessories
C-more touch panels can be enhanced with the accessories below:

Accessory Locations
CM5-T7W, CM5-T10W, CM5-T12W, CM5-T15W, CM5-T22W

Mga SD Card
EA-SD-CARD
MSD-SLC16G

SD memory cards for non-volatile storage, 2GB or 16GB industrial grade. High operating temperature make EA-SD-CARD and MSD-SLC16G suitable for data logging in industrial applications. These cards are recommended for C-more CM5 series.
EA-SD-CARD and MSD-SLC16G utilize SLC technology so they are the fastest and most reliable option for writing and storing data. If logged data is saved to external memory, AutomationDirect recommends using EA-SD-CARD. and MSDSLC16G.
SLC Flash has the longest lifespan of flash types and can operate in a broader temperature range than other types.
EA-SD-CARD and MSD-SLC16G with SLC Flash memory is recommended for industrial workloads that require heavy read/write cycles.

USB Flash Drive
USB-FLASH

USB-FLASH sold by AutomationDirect has been tested with C-more HMIs and is Hi-Speed USB 2.0 certified. The MSD-SLC16G is the best option for logging data, but the USB-FLASH is a high-quality flash drive perfect for transferring log files, capturing screens, backing up and restoring projects and storing images for the Image Viewer object.
D-SUB 15-pin to Terminal Block Adapter – Right Angle
The EA-COMCON-3 adapter plugs into the 15-pin serial port on the rear of a panel to allow wire terminal connections for an RS-422/RS-485 communication cable. For use with C-more Micro EA1 series 4in and 6in HMIs, C-more Micro EA3 series 3in, 4in, and 6in HMIs, C-more EA9 series 6in and 7in HMIs, C-more CM5 series 4in HMI.
EA-COMCON-3

D-SUB 15-pin to Terminal Block Adapter – Straight Through
The EA-COMCON-3A adapter plugs into the 15-pin serial port on the rear of a panel to allow wire terminal connections for an RS-422/RS-485 communication cable. For use with C-more Micro EA1 series 3in with EA1-MG-SP1, C-more Micro EA3 series 8in and 10in HMIs, C-more EA9 series 8in, 10in, 12in and 15in HMIs, C-more CM5 series Headless, 7in, 10in, 12in, 15in,and 22in HMIs. The EA-COMCON-3A is not UL recognized or listed.
EA-COMCON-3A


Non-glare Screen Covers (in packages of 3)
The non-glare screen covers are protective overlays used to protect the touch screen while helping to reduce the glare from external light sources.
Mga Numero ng Bahagi: HMI-4W-COV, HMI-7W-COV, HMI-10W-COV, HMI-12W-COV, HMI-15W-COV, HMI-22W-COV

HMI-4W-COV $44.50
HMI-7W-COV $51.00
HMI-10W-COV $59.00
HMI-12W-COV $43.00
HMI-15W-COV $49.00
HMI-22W-COV $73.00

Pag-install

TANDAAN: The Protective Cover ships with a thin protective sheet on the face of the cover that needs to be carefully removed. If your panel is not clear, the protective sheet may not have been removed.
Mga Kapalit na Bahagi
These replacement parts can be used to replace damaged, worn or lost C-more components.
Replacement parts at a glance:


Software ng Programming
CM5-PGMSW -FREE Download!
C-more Programming Software can be downloaded at no charge or a USB version may be purchased by ordering CM5-PGMSW. The software requires a USB port or Ethernet connection* on your PC to connect to the C-more panel. Software Help Files are included in the download. This software programs all the C-more panels.
CM5-PGMSW USB Flash Drive

Mga Tampok ng Software
- Over 50 objects including 16 pen trends, switches, PID trend faceplate, PID bar graph
- Event Manager allows for logging and notifications
- Language support for objects in German, French, Italian, Spanish, Chinese and Japanese Characters
- Project simulator
- Bitmap animation
- E-mail messaging
- Built-in FTP server / Webserver (Secure HTTPs)
- Popup windows
- Data logging to USB/SD flash drive
- USB 2.0 Type B port for programming
- Historical alarms with time and date stamp along with alarm frequency reporting
- Supports simultaneous communication to multiple brands of PLC/PACs
- Mouse and keyboard support within the project
- Remote HMI feature with smart phone / tablet / PC
- 2 taong warranty
Mga Kinakailangan sa Computer System
CM5-PGMSW will run on PCs that meet the following requirements:
- Windows OS: 8: 32 & 64 bit, 8.1: 32 & 64 bit, 10, 11
- 2GB of available memory
- 1GB puwang ng hard drive
- Available Ethernet or USB port
Mga FAQ
How can I resolve a Not enough Memory Space error?
To resolve this error, consider optimizing memory usage on the device or connecting to a device with larger memory capacity.
What should I do if I encounter a Handshake Timeout Error?
Check your network connection, ensure proper settings for Recipe or Numeric Entry Objects, and try restarting the communication process.
How can I troubleshoot an Email Connection Error?
Verify the email server settings, check network connectivity,and ensure correct email address configuration on the touch panel.
Mga Dokumento / Mga Mapagkukunan
![]() |
AutomationDirect CM5 Series Color Tft LCD Touch Screen [pdf] User Manual CM5-RHMI-USER-M, CM5 Series Color Tft LCD Touch Screen, CM5 Series, Color Tft LCD Touch Screen, LCD Touch Screen, Touch Screen |